Publications

Export 83 results:
Author [ Title(Desc)] Type Year
Filters: Author is Antoni Ivorra  [Clear All Filters]
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 
3
Castellví Q, Banús J, Ivorra A. 3D Assessment of Irreversible Electroporation Treatments in Vegetal Models. In: Jarm T, Kramar P 1st World Congress on Electroporation and Pulsed Electric Fields in Biology, Medicine and Food & Environmental Technologies. Vol. 53. 1st World Congress on Electroporation and Pulsed Electric Fields in Biology, Medicine and Food & Environmental Technologies. Springer Singapore; 2016. pp. 294-297. Available from: http://dx.doi.org/10.1007/978-981-287-817-5_65 (348.63 KB)
A
Qasrawi R, Silve L, Burdío F, Abdeen Z, Ivorra A. Anatomically Realistic Simulations of Liver Ablation by Irreversible Electroporation: Impact of Blood Vessels on Ablation Volumes and Undertreatment. Technology in Cancer Research & Treatment. 2017 ;[Epub ahead of print]. (1.15 MB)
Castellví Q, Mercadal B, Ivorra A. Assessment of Electroporation by Electrical Impedance Methods. In: Handbook of Electroporation. Handbook of Electroporation. Springer International Publishing; 2016. pp. 1-20 (electronic).
Brambilla-Pisoni C, Muñoz-Moreno E, Gallego-Amaro I, Maldonado R, Ivorra A, Soria G, Ozaita A. Auricular transcutaneous vagus nerve stimulation acutely modulates brain connectivity in mice. Frontiers in Cellular Neuroscience [Internet]. 2022 ;16:856855. Available from: https://www.frontiersin.org/articles/10.3389/fncel.2022.856855/abstract
Vázquez-Oliver A, Brambilla-Pisoni C, Domingo-Gainza M, Maldonado R, Ivorra A, Ozaita A. Auricular transcutaneous vagus nerve stimulation improves memory persistence in naïve mice and in an intellectual disability mouse model. Brain Stimulation [Internet]. 2020 ;13(12):494-498. Available from: https://doi.org/10.1016/j.brs.2019.12.024
Mercadal B, Arena C, Davalos R, Ivorra A. Avoiding nerve stimulation in irreversible electroporation: a numerical modeling study. Physics in Medicine and Biology. 2017 ;62(20):8060-8079. (1004.9 KB)
Castellví Q, Mercadal B, Moll X, Fontdevila D, Andaluz A, Ivorra A. Avoiding neuromuscular stimulation in liver irreversible electroporation using radiofrequency electric fields. Physics in Medicine and Biology. 2018 ;63(3):035027. (1.33 MB)
B
Becerra-Fajardo L, Ivorra A. Bidirectional communications in wireless microstimulators based on electronic rectification of epidermically applied currents. In: Neural Engineering (NER), 2015 7th International IEEE/EMBS Conference on. Neural Engineering (NER), 2015 7th International IEEE/EMBS Conference on. ; 2015. (738.6 KB)
C
Trujillo M, Castellví Q, Burdío F, Sánchez-Velázquez P, Ivorra A, Andaluz A, Berjano E. Can electroporation previous to radiofrequency hepatic ablation enlarge thermal lesion size? A feasibility study based on theoretical modelling and in vivo experiments. International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group [Internet]. 2013 ;29:211–8. © 2013 Informa UK Ltd. Available from: http://www.ncbi.nlm.nih.gov/pubmed/23573935 (586.06 KB)
Becerra-Fajardo L, Ivorra A. Charge Counter for Performing Active Charge-Balance in Miniaturized Electrical Stimulators. In: Lacković I, Vasic D 6th European Conference of the International Federation for Medical and Biological Engineering SE - 64. Vol. 45. 6th European Conference of the International Federation for Medical and Biological Engineering SE - 64. Springer International Publishing; 2015. pp. 256 - 259. Available from: http://dx.doi.org/10.1007/978-3-319-11128-5_64 (393.72 KB)
Klein N, Guenther E, Botea F, Pautov M, Dima S, Tomescu D, Popescu M, Ivorra A, Stehling M, Popescu I. The combination of electroporation and electrolysis (E2) employing different electrode arrays for ablation of large tissue volumes. PLoS One [Internet]. 2019 ;14(8):e0221393. Available from: https://doi.org/10.1371/journal.pone.0221393
Heller E, Garcia-Sanchez T, Moshkovits Y, Rabinovici R, Grynberg D, Segev A, Asirvatham S, Ivorra A, Maor E. Comparing High-Frequency With Monophasic Electroporation Protocols in an In Vivo Beating Heart Model. JACC: Clinical Electrophysiology. 2021 ;7(8):959-964. (1.31 MB)
Silve A, A. Brunet G, Al-Sakere B, Ivorra A, Mir LM. Comparison of the effects of the repetition rate between microsecond and nanosecond pulses: Electropermeabilization-induced electro-desensitization?. Biochimica et Biophysica Acta (BBA) - General Subjects [Internet]. 2014 ;1840:2139 - 2151. Available from: http://www.sciencedirect.com/science/article/pii/S0304416514000725
Gómez-Barea M, Garcia-Sanchez T, Ivorra A. A computational comparison of Radiofrequency and Pulsed Field Ablation in terms of lesion morphology in the cardiac chamber. Scientific Reports [Internet]. 2022 ;12. Available from: https://doi.org/10.1038/s41598-022-20212-9
D
Becerra-Fajardo L, Schmidbauer M, Ivorra A. Demonstration of 2 mm thick microcontrolled injectable stimulators based on rectification of high frequency current bursts. IEEE Transactions on Neural Systems and Rehabilitation Engineering. 2017 ;25(8):1343 - 1352. (969.52 KB)
Mercadal B, P. Vernier T, Ivorra A. Dependence of electroporation detection threshold on cell radius: an explanation to observations non compatible with Schwan’s equation model. Journal of Membrane Biology. 2016 ;249(5):663-676. (1.01 MB)
Ruiz-Vargas A, Ivorra A, Arkwright JW. Design, Construction and Validation of an Electrical Impedance Probe with Contact Force and Temperature Sensors Suitable for in-vivo Measurements. Scientific Reports. 2018 ;8:14818. (2.3 MB)
Silve A, Ivorra A, Mir LM. Detection of permeabilisation obtained by micropulses and nanopulses by means of bioimpedance of biological tissues. In: 5th European Conference on Antennas and Propagation (EUCAP). 5th European Conference on Antennas and Propagation (EUCAP). Rome, Italy; 2011. pp. 3164–3167. © 2011 Institute of Electrical and Electronics Engineers, Inc. (1012.2 KB)
Mercadal B, Beitel-White N, Aycock KN, Castellví Q, Davalos R, Ivorra A. Dynamics of Cell Death After Conventional IRE and H-FIRE Treatments. Annals of Biomedical Engineering [Internet]. 2020 ;48:1451–1462. Available from: https://doi.org/10.1007/s10439-020-02462-8
Amorós-Figueras G, Casabella-Ramon S, Moreno-Weidmann Z, Ivorra A, Guerra JM, Garcia-Sanchez T. Dynamics of High-Density Unipolar Epicardial Electrograms During PFA. Circulation: Arrhythmia and Electrophysiology [Internet]. 2023 :e011914. Available from: https://www.ahajournals.org/doi/10.1161/CIRCEP.123.011914
E
Ewertowska E, Mercadal B, Muñoz V, Ivorra A, Trujillo M, Berjano E. Effect of applied voltage, duration and repetition frequency of RF pulses for pain relief on temperature spikes and electrical field: A computer modeling study. International Journal of Hyperthermia [Internet]. 2018 ;34(1):112-121. Available from: http://dx.doi.org/10.1080/02656736.2017.1323122 (676.96 KB)
Nakagawa H, Castellví Q, Neal R, Girouard S, Laughner J, Ikeda A, Sugawara M, An Y, Hussein AA, Nakhla S, et al. Effects of Contact Force on Lesion Size During Pulsed Field Catheter Ablation: Histochemical Characterization of Ventricular Lesion Boundaries. Circulation: Arrhythmia and Electrophysiology [Internet]. 2023 ;(Online ahead of print.):e012026. Available from: https://doi.org/10.1161/CIRCEP.123.012026
Ivorra A, Rubinsky B, Mir LM. Electric field redistribution during tissue electroporation: its potential impact on treatment planning. Comptes Rendus Physique. 2010 ;Accepted (still pending publication). (527.24 KB)
Laufer S, Ivorra A, Reuter VE, Rubinsky B, Solomon SB. Electrical impedance characterization of normal and cancerous human hepatic tissue. Physiological measurement [Internet]. 2010 ;31:995–1009. © 2010 Institute of Physics and IOP Publishing Limited. Available from: http://www.ncbi.nlm.nih.gov/pubmed/20577035 (710.34 KB)
Ivorra A, Villemejane J, Mir LM. Electrical modeling of the influence of medium conductivity on electroporation. Physical chemistry chemical physics : PCCP [Internet]. 2010 ;12:10055–64. Available from: http://www.ncbi.nlm.nih.gov/pubmed/20585676 (3.14 MB)

Pages