lbecerra

Primary tabs

2017
Becerra-Fajardo L, Schmidbauer M, Ivorra A. Demonstration of 2 mm thick microcontrolled injectable stimulators based on rectification of high frequency current bursts. IEEE Transactions on Neural Systems and Rehabilitation Engineering. 2017 ;25(8):1343 - 1352. (969.52 KB)
Becerra-Fajardo L, Garcia-Arnau R, Ivorra A. Injectable Stimulators Based on Rectification of High Frequency Current Bursts: Power Efficiency of 2 mm Thick Prototypes. In: Ibáñez J, González-Vargas J, Azorín JMaría, Akay M, Pons JLuis Converging Clinical and Engineering Research on Neurorehabilitation II: Proceedings of the 3rd International Conference on NeuroRehabilitation (ICNR2016), October 18-21, 2016, Segovia, Spain. Converging Clinical and Engineering Research on Neurorehabilitation II: Proceedings of the 3rd International Conference on NeuroRehabilitation (ICNR2016), October 18-21, 2016, Segovia, Spain. Cham: Springer International Publishing; 2017. Available from: http://dx.doi.org/10.1007/978-3-319-46669-9_110 (941.97 KB)
2015
Becerra-Fajardo L, Ivorra A. Bidirectional communications in wireless microstimulators based on electronic rectification of epidermically applied currents. In: Neural Engineering (NER), 2015 7th International IEEE/EMBS Conference on. Neural Engineering (NER), 2015 7th International IEEE/EMBS Conference on. ; 2015. (738.6 KB)
Becerra-Fajardo L, Ivorra A. Charge Counter for Performing Active Charge-Balance in Miniaturized Electrical Stimulators. In: Lacković I, Vasic D 6th European Conference of the International Federation for Medical and Biological Engineering SE - 64. Vol. 45. 6th European Conference of the International Federation for Medical and Biological Engineering SE - 64. Springer International Publishing; 2015. pp. 256 - 259. Available from: http://dx.doi.org/10.1007/978-3-319-11128-5_64 (393.72 KB)
Becerra-Fajardo L, Ivorra A. In Vivo Demonstration of Addressable Microstimulators Powered by Rectification of Epidermically Applied Currents for Miniaturized Neuroprostheses. Plos One [Internet]. 2015 ;10(7). Available from: http://dx.doi.org/10.1371%2Fjournal.pone.0131666 (957.02 KB)
Ivorra A, Becerra-Fajardo L, Castellví Q. In vivo demonstration of injectable microstimulators based on charge-balanced rectification of epidermically applied currents. Journal of Neural Engineering. 2015 ;12(6). (1.06 MB)
2014
Ivorra A, Becerra-Fajardo L. Flexible Thread-like Electrical Stimulation Implants Based on Rectification of Epidermically Applied Currents Which Perform Charge Balance. International Conference on NeuroRehabilitation ICNR2014. 2014 . (755.69 KB)
Becerra-Fajardo L, Ivorra A. Towards addressable wireless microstimulators based on electronic rectification of epidermically applied currents. In: Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Chicago: IEEE; 2014. pp. 3973 - 3976. (414.25 KB)
2013
Ivorra A, Becerra-Fajardo L. Wireless Microstimulators Based on Electronic Rectification of Epidermically Applied Currents: Safety and Portability Analysis. In: 18th IFESS Annual Conference. 18th IFESS Annual Conference. Donostia-San Sebastián, Spain; 2013. pp. 213–216. (2.64 MB)
2012
Becerra-Fajardo L, Ivorra A. Proof of Concept of a Stimulator Based on AC Current Rectification for Neuroprosthetics. In: XXX Congreso Anual de la Sociedad Española de Ingeniría Biomédica. XXX Congreso Anual de la Sociedad Española de Ingeniría Biomédica. San Sebastián, Spain; 2012. (298.89 KB)