Publications
In Vitro Evaluation of a Protocol and an Architecture for Bidirectional Communications in Networks of Wireless Implants Powered by Volume Conduction. In: 5th International Conference on Neurorehabilitation (ICNR2020). Vol. 28. Converging Clinical and Engineering Research on Neurorehabilitation IV, Biosystems & Biorobotics. 5th International Conference on Neurorehabilitation (ICNR2020). Springer Nature; 2020. pp. 103-108.
(254.09 KB)
. 
In vitro study on the mechanisms of action of electrolytic electroporation (E2). Bioelectrochemistry [Internet]. 2020 ;133:107482. Available from: https://doi.org/10.1016/j.bioelechem.2020.107482
. Injectable Sensors Based on Passive Rectification of Volume-Conducted Currents. IEEE Transactions on Biomedical Circuits and Systems [Internet]. 2020 ;14(4):867-878. Available from: https://ieeexplore.ieee.org/document/9117042
. Interleaved intramuscular stimulation with minimally overlapping electrodes evokes smooth and fatigue resistant forces. Journal of Neural Engineering [Internet]. 2020 ;17(4):046037. Available from: https://doi.org/10.1088/1741-2552/aba99e
. Monitoring the molecular composition of live cells exposed to electric pulses via label-free optical methods. Scientific Reports [Internet]. 2020 ;10:10471. Available from: https://doi.org/10.1038/s41598-020-67402-x
. Physiological changes may dominate the electrical properties of liver during reversible electroporation: measurements and modelling. Bioelectrochemistry [Internet]. 2020 ;(In Press, Journal Pre-proof). Available from: https://doi.org/10.1016/j.bioelechem.2020.107627
. Possible molecular and cellular mechanisms at the basis of atmospheric electromagnetic field bioeffects. International Journal of Biometeorology [Internet]. 2020 ;(In Press, available online). Available from: https://doi.org/10.1007/s00484-020-01885-1
. Power Transfer by Volume Conduction: In Vitro Validated Analytical Models Predict DC Powers above 1 mW in Injectable Implants. IEEE Access. 2020 ;8(1):37808-37820.
(1.27 MB)
. 
Pulsed radiofrequency for chronic pain: in vitro evidence of an electroporation mediated calcium uptake. Bioelectrochemistry. 2020 ;136:107624.
(1001.17 KB)
. 
The combination of electroporation and electrolysis (E2) employing different electrode arrays for ablation of large tissue volumes. PLoS One [Internet]. 2019 ;14(8):e0221393. Available from: https://doi.org/10.1371/journal.pone.0221393
. Industrial Electronics for Biomedicine: A New Cancer Treatment Using Electroporation. IEEE Industrial Electronics Magazine. 2019 ;13(4):6-18.
. Successful tumor Electrochemotherapy using Sine Waves. IEEE Transactions on Biomedical Engineering. 2019 ;67(4):1040-1049.
. Avoiding neuromuscular stimulation in liver irreversible electroporation using radiofrequency electric fields. Physics in Medicine and Biology. 2018 ;63(3):035027.
(1.33 MB)
. 
Design, Construction and Validation of an Electrical Impedance Probe with Contact Force and Temperature Sensors Suitable for in-vivo Measurements. Scientific Reports. 2018 ;8:14818.
(2.3 MB)
. 
Effect of applied voltage, duration and repetition frequency of RF pulses for pain relief on temperature spikes and electrical field: A computer modeling study. International Journal of Hyperthermia [Internet]. 2018 ;34(1):112-121. Available from: http://dx.doi.org/10.1080/02656736.2017.1323122
(676.96 KB)
. 
First Steps Towards an Implantable Electromyography (EMG) Sensor Powered and Controlled by Galvanic Coupling. In: World Congress on Medical Physics and Biomedical Engineering 2018. IFMBE Proceedings. Vol. 68/3. World Congress on Medical Physics and Biomedical Engineering 2018. IFMBE Proceedings. Prague, Czech Republic: Springer; 2018. pp. 19-22.
(438.15 KB)
. 
Impedance spectroscopy measurements as a tool for distinguishing different luminal content during bolus transit studies. Neurogastroenterology and Motility. 2018 ;30(6):e13274.
(1.16 MB)
. 
Irreversible electroporation for the treatment of cardiac arrhythmias. Expert Review of Cardiovascular Therapy [Internet]. 2018 ;16(5):349-360 . Available from: https://www.tandfonline.com/doi/abs/10.1080/14779072.2018.1459185
. Modeling Liver Electrical Conductivity during Hypertonic Injection. International Journal for Numerical Methods in Biomedical Engineering. 2018 ;34(1):e2904.
(634.63 KB)
. 
Monitoring the Effect of Contact Pressure on Bioimpedance Measurements. In: 018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). 018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). ; 2018. pp. 4949-4952.
. Numerical analysis of thermal impact of intramyocardial capillary blood flow during radiofrequency cardiac ablation. International Journal of Hyperthermia. 2018 ;34(3):243-249.
(893.29 KB)
. 
Powering Implants by Galvanic Coupling: A Validated Analytical Model Predicts Powers Above 1 mW in Injectable Implants. In: World Congress on Medical Physics and Biomedical Engineering 2018. IFMBE Proceedings. Vol. 68/3. World Congress on Medical Physics and Biomedical Engineering 2018. IFMBE Proceedings. Prague, Czech Republic: Springer; 2018. pp. 23-26.
(272.06 KB)
. 
Relation between Denaturation Time Measured by Optical Coherence Reflectometry and Thermal Lesion Depth during Radiofrequency Cardiac Ablation: Feasibility Numerical Study. Lasers in surgery and medicine. 2018 ;50(3):222-229.
(670.46 KB)
. 
RF-Energized Intracoronary Guidewire to Enhance Bipolar Ablation of the Interventricular Septum: In-silico Feasibility Study. International Journal of Hyperthermia [Internet]. 2018 ;34(8):1202-1212. Available from: https://www.tandfonline.com/doi/full/10.1080/02656736.2018.1425487
. Should fluid dynamics be included in computer models of RF cardiac ablation by irrigated-tip electrodes?. BioMedical Engineering OnLine [Internet]. 2018 ;17(1):43. Available from: https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5910590/
.