Publications
Demonstration of 2 mm thick microcontrolled injectable stimulators based on rectification of high frequency current bursts. IEEE Transactions on Neural Systems and Rehabilitation Engineering. 2017 ;25(8):1343 - 1352. (969.52 KB)
. Electronic System Having Variable Modular Power for Generating Electrical Pulses and Associated Uses. 2017 .
. Focused Transhepatic Electroporation Mediated by Hypersaline Infusion throuth the Portal Vein in Rat Model. Preliminary Results on Differential Conductivity. Radiology and Oncology. 2017 ;51(4):415-421. (847.11 KB)
Injectable Stimulators Based on Rectification of High Frequency Current Bursts: Power Efficiency of 2 mm Thick Prototypes. In: Converging Clinical and Engineering Research on Neurorehabilitation II: Proceedings of the 3rd International Conference on NeuroRehabilitation (ICNR2016), October 18-21, 2016, Segovia, Spain. Converging Clinical and Engineering Research on Neurorehabilitation II: Proceedings of the 3rd International Conference on NeuroRehabilitation (ICNR2016), October 18-21, 2016, Segovia, Spain. Cham: Springer International Publishing; 2017. Available from: http://dx.doi.org/10.1007/978-3-319-46669-9_110 (941.97 KB)
. Long-term effectiveness of irreversible electroporation in a murine model of colorectal liver metastasis. Scientific reports. 2017 ;7. (1.5 MB)
3D Assessment of Irreversible Electroporation Treatments in Vegetal Models. In: 1st World Congress on Electroporation and Pulsed Electric Fields in Biology, Medicine and Food & Environmental Technologies. Vol. 53. 1st World Congress on Electroporation and Pulsed Electric Fields in Biology, Medicine and Food & Environmental Technologies. Springer Singapore; 2016. pp. 294-297. Available from: http://dx.doi.org/10.1007/978-981-287-817-5_65 (348.63 KB)
. Assessment of Electroporation by Electrical Impedance Methods. In: Handbook of Electroporation. Handbook of Electroporation. Springer International Publishing; 2016. pp. 1-20 (electronic).
. Dependence of electroporation detection threshold on cell radius: an explanation to observations non compatible with Schwan’s equation model. Journal of Membrane Biology. 2016 ;249(5):663-676. (1.01 MB)
. Incorporation of the Blood Vessel Wall into Electroporation Simulations. In: 1st World Congress on Electroporation and Pulsed Electric Fields in Biology, Medicine and Food & Environmental Technologies. Vol. 53. 1st World Congress on Electroporation and Pulsed Electric Fields in Biology, Medicine and Food & Environmental Technologies. Springer Singapore; 2016. pp. 223-227. Available from: http://dx.doi.org/10.1007/978-981-287-817-5_50 (482.64 KB)
. Irreversible electroporation of the liver: is there a safe limit to the ablation volume?. Scientific Reports. 2016 ;6:23781. (692.79 KB)
A Versatile Multilevel Converter Platform for Cancer Treatment Using Irreversible Electroporation. IEEE Journal of Emerging and Selected Topics in Power Electronics. 2016 ;4(1):236 - 242. (1.8 MB)
. Bidirectional communications in wireless microstimulators based on electronic rectification of epidermically applied currents. In: Neural Engineering (NER), 2015 7th International IEEE/EMBS Conference on. Neural Engineering (NER), 2015 7th International IEEE/EMBS Conference on. ; 2015. (738.6 KB)
. Charge Counter for Performing Active Charge-Balance in Miniaturized Electrical Stimulators. In: 6th European Conference of the International Federation for Medical and Biological Engineering SE - 64. Vol. 45. 6th European Conference of the International Federation for Medical and Biological Engineering SE - 64. Springer International Publishing; 2015. pp. 256 - 259. Available from: http://dx.doi.org/10.1007/978-3-319-11128-5_64 (393.72 KB)
. Impact of Liver Vasculature on Electric Field Distribution during Electroporation Treatments: An Anatomically Realistic Numerical Study. In: 6th European Conference of the International Federation for Medical and Biological Engineering. Vol. 45. 6th European Conference of the International Federation for Medical and Biological Engineering. Springer International Publishing; 2015. pp. 573-576. Available from: http://dx.doi.org/10.1007/978-3-319-11128-5_143 (300.12 KB)
. In Vivo Demonstration of Addressable Microstimulators Powered by Rectification of Epidermically Applied Currents for Miniaturized Neuroprostheses. Plos One [Internet]. 2015 ;10(7). Available from: http://dx.doi.org/10.1371%2Fjournal.pone.0131666 (957.02 KB)
. In vivo demonstration of injectable microstimulators based on charge-balanced rectification of epidermically applied currents. Journal of Neural Engineering. 2015 ;12(6). (1.06 MB)
. Selective Electroporation of Liver Tumor Nodules by Means of Hypersaline Infusion: A Feasibility Study. In: 6th European Conference of the International Federation for Medical and Biological Engineering. Vol. 45. 6th European Conference of the International Federation for Medical and Biological Engineering. Springer International Publishing; 2015. pp. 821-824. Available from: http://dx.doi.org/10.1007/978-3-319-11128-5_204 (367.54 KB)
. Tumor growth delay by adjuvant alternating electric fields which appears non-thermally mediated. Bioelectrochemistry. 2015 ;105:16 - 24. (1.24 MB)
. Bioimpedance Measurements and the Electroporation Phenomenon. Revue 3EI. 2014 ;75:21-26. (1.02 MB)
. Comparison of the effects of the repetition rate between microsecond and nanosecond pulses: Electropermeabilization-induced electro-desensitization?. Biochimica et Biophysica Acta (BBA) - General Subjects [Internet]. 2014 ;1840:2139 - 2151. Available from: http://www.sciencedirect.com/science/article/pii/S0304416514000725
. Fast flow-through non-thermal pasteurization using constant radiofrequency electric fields. Innovative Food Science and Emerging Technologies. 2014 ;22:pp.116-123. (978.85 KB)
. Flexible Thread-like Electrical Stimulation Implants Based on Rectification of Epidermically Applied Currents which Perform Charge Balance. In: 2nd International Conference on NeuroRehabilitation (ICNR2014), Aalborg, 24-26 June, 2014. 2nd International Conference on NeuroRehabilitation (ICNR2014), Aalborg, 24-26 June, 2014. Aalborg, Denmark: Springer; 2014. pp. 447-455. (755.69 KB)
. . Towards addressable wireless microstimulators based on electronic rectification of epidermically applied currents. In: Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Chicago: IEEE; 2014. pp. 3973 - 3976. (414.25 KB)
. Can electroporation previous to radiofrequency hepatic ablation enlarge thermal lesion size? A feasibility study based on theoretical modelling and in vivo experiments. International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group [Internet]. 2013 ;29:211–8. © 2013 Informa UK Ltd. Available from: http://www.ncbi.nlm.nih.gov/pubmed/23573935 (586.06 KB)
.