
Publications
. Demonstration of 2 mm thick microcontrolled injectable stimulators based on rectification of high frequency current bursts. IEEE Transactions on Neural Systems and Rehabilitation Engineering. 2017 ;25(8):1343 - 1352.
(969.52 KB)
. Computational Multiscale Modeling of Pulsed Field Ablation Considering Conductivity and Damage Anisotropy Reveals Deep Lesion Morphologies. International Journal for Numerical Methods in Biomedical Engineering [Internet]. 2025 ;1(8): e70077. Available from: https://doi.org/10.1002/cnm.70077
(913.16 KB)
. A computational comparison of Radiofrequency and Pulsed Field Ablation in terms of lesion morphology in the cardiac chamber. Scientific Reports [Internet]. 2022 ;12. Available from: https://doi.org/10.1038/s41598-022-20212-9
. Comparison of the effects of the repetition rate between microsecond and nanosecond pulses: Electropermeabilization-induced electro-desensitization?. Biochimica et Biophysica Acta (BBA) - General Subjects [Internet]. 2014 ;1840:2139 - 2151. Available from: http://www.sciencedirect.com/science/article/pii/S0304416514000725
. Comparing High-Frequency With Monophasic Electroporation Protocols in an In Vivo Beating Heart Model. JACC: Clinical Electrophysiology. 2021 ;7(8):959-964.
(1.31 MB)
. The combination of electroporation and electrolysis (E2) employing different electrode arrays for ablation of large tissue volumes. PLoS One [Internet]. 2019 ;14(8):e0221393. Available from: https://doi.org/10.1371/journal.pone.0221393
. Changes in local endocardial electrograms immediately after PFA show dose-dependent variations. EP Europace [Internet]. 2024 ;26(Issue Supplement_1):euae102.755. Available from: https://academic.oup.com/europace/article/26/Supplement_1/euae102.755/7681509
. Can electroporation previous to radiofrequency hepatic ablation enlarge thermal lesion size? A feasibility study based on theoretical modelling and in vivo experiments. International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group [Internet]. 2013 ;29:211–8. © 2013 Informa UK Ltd. Available from: http://www.ncbi.nlm.nih.gov/pubmed/23573935
(586.06 KB)
. Calcium signaling hacking by MILD electroporation: a novel approach for bioelectronic medicine. Bioelectricity [Internet]. 2025 ;Ahead of Print. Available from: https://doi.org/10.1177/25763113251401800
(651.9 KB)
The Biomedical Engineer’s Pledge: Overview and Context. Medical & Biological Engineering & Computing [Internet]. 2025 ;(Published online). Available from: https://doi.org/10.1007/s11517-025-03443-6
. Avoiding neuromuscular stimulation in liver irreversible electroporation using radiofrequency electric fields. Physics in Medicine and Biology. 2018 ;63(3):035027.
(1.33 MB)
. Avoiding nerve stimulation in irreversible electroporation: a numerical modeling study. Physics in Medicine and Biology. 2017 ;62(20):8060-8079.
(1004.9 KB)
. Auricular transcutaneous vagus nerve stimulation improves memory persistence in naïve mice and in an intellectual disability mouse model. Brain Stimulation [Internet]. 2020 ;13(12):494-498. Available from: https://doi.org/10.1016/j.brs.2019.12.024
. Auricular transcutaneous vagus nerve stimulation acutely modulates brain connectivity in mice. Frontiers in Cellular Neuroscience [Internet]. 2022 ;16:856855. Available from: https://www.frontiersin.org/articles/10.3389/fncel.2022.856855/abstract
Atrial fibrillation and flutter conversion with pulsed electric field delivery: preclinical proof of concept. Journal of Interventional Cardiac Electrophysiology [Internet]. 2025 . Available from: https://doi.org/10.1007/s10840-025-02115-7
. Anatomically Realistic Simulations of Liver Ablation by Irreversible Electroporation: Impact of Blood Vessels on Ablation Volumes and Undertreatment. Technology in Cancer Research & Treatment. 2017 ;[Epub ahead of print].
(1.15 MB)
. Wireless Microstimulators Based on Electronic Rectification of Epidermically Applied Currents: Safety and Portability Analysis. In: 18th IFESS Annual Conference. 18th IFESS Annual Conference. Donostia-San Sebastián, Spain; 2013. pp. 213–216.
(2.64 MB)
. Two-Port Networks to Model Galvanic Coupling for Intrabody Communications and Power Transfer to Implants. In: 2018 IEEE Biomedical Circuits and Systems Conference (BioCAS). 2018 IEEE Biomedical Circuits and Systems Conference (BioCAS). ; 2018. pp. 407-410.
(590.36 KB)
. Towards addressable wireless microstimulators based on electronic rectification of epidermically applied currents. In: Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Chicago: IEEE; 2014. pp. 3973 - 3976.
(414.25 KB)
. Selective Electroporation of Liver Tumor Nodules by Means of Hypersaline Infusion: A Feasibility Study. In: 6th European Conference of the International Federation for Medical and Biological Engineering. Vol. 45. 6th European Conference of the International Federation for Medical and Biological Engineering. Springer International Publishing; 2015. pp. 821-824. Available from: http://dx.doi.org/10.1007/978-3-319-11128-5_204
(367.54 KB)
. Proof of Concept of a Stimulator Based on AC Current Rectification for Neuroprosthetics. In: XXX Congreso Anual de la Sociedad Española de Ingeniría Biomédica. XXX Congreso Anual de la Sociedad Española de Ingeniría Biomédica. San Sebastián, Spain; 2012.
(298.89 KB)
. Powering Implants by Galvanic Coupling: A Validated Analytical Model Predicts Powers Above 1 mW in Injectable Implants. In: World Congress on Medical Physics and Biomedical Engineering 2018. IFMBE Proceedings. Vol. 68/3. World Congress on Medical Physics and Biomedical Engineering 2018. IFMBE Proceedings. Prague, Czech Republic: Springer; 2018. pp. 23-26.
(272.06 KB)
. Networks of Injectable Microdevices Powered and Digitally Linked by Volume Conduction for Neuroprosthetics: a Proof-of-Concept. In: 2023 11th International IEEE/EMBS Conference on Neural Engineering (NER). 2023 11th International IEEE/EMBS Conference on Neural Engineering (NER). ; 2023. Available from: https://ieeexplore.ieee.org/abstract/document/10123743
(735.35 KB)
. Monitoring the Effect of Contact Pressure on Bioimpedance Measurements. In: 018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). 018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). ; 2018. pp. 4949-4952.
. Irreversible Electroporation for Tissue Ablation. In: 5th Course ("Medical Applications of Electromagnetic Fields: Research and Therapy") of the School of Bioelectromagnetism Alessadro Chiabreara. 5th Course ("Medical Applications of Electromagnetic Fields: Research and Therapy") of the School of Bioelectromagnetism Alessadro Chiabreara. ; 2010.

]